Smart RS232 10KVA / 8000W AC power 60 Hz 110V UPS with bypass repair switch

Minimum Order Quantity : USD10000 Packaging Details : Standard Exported Cartons and Pallets
Delivery Time : Within 15-30days after receiving your 30% TT deposit Payment Terms : 30% TT in advance, the balance before shipping
Supply Ability : 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS
Place of Origin: China Brand Name: SOROTEC
Certification: CE,ROHS,ISO9000 Model Number: HP9116C 6-10KVA

Detail Information

Rated Voltage: 200/208VAC Frequency: 50/60 Hz
Voltage Range: 176~279VAC(±3VAC) Frequency Range: 50HZ:(46~54HZ); 60HZ:(56HZ~64HZ)
Power Factor: 0.98 Voltage Regulation: 200/208X (1±2%)VAC
Frequency Regulation: 50/60 Hz±0.05Hz Power Factor: 0.7/0.8(Optional) Standard 0.7
Current Crest Ratio: 3:1 DC Voltage: 240VDC
High Light:

ups uninterruptible power supply

,

pure sine wave ups

Product Description

Smart RS232 10KVA / 8000W AC power 60 Hz 110V UPS with bypass repair switch

 

 

Key Features:
1.Large blue back light LCD for detailed Real-time UPS status display.


2.Advanced online pure sine wave power supply system, with bypass repair switch, It can
provide a reliable, high quality AC power source to the precision equipments, can be used widely in different fields.


3.Widely used to computer equipments, telecommunication systems and Industrial automatic control equipments.


4.Truly online design, different from offline, it can adjust the input voltage, filtering, when the AC break off, the UPS will provide an uninterruptible power source from the backup batteries.


5.UPS will change to bypass mode when overloading or inverter fault, when overloading remove, UPS will turn to inverter mode automatically.


6.N+N Parallel Redundancy and Capacity expansion for 6-20K(up to three units)


 

Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom…
 

 


Technical Specifications of Online UPS HP9116B 6-10K (1Ph in/1Ph out)

Model HP9116C 6-10KVA
6KT 6KT-XL 10KT 10KT-XL
Rated Power 6KVA/4.2KW 10KVA/7KW
Rated Voltage 220/230/240VAC
Rated Frequency 50/60 Hz
Input
Voltage Range 176~279VAC (±3VAC)
Frequency Range 50HZ: (46~54HZ); 60HZ:(56HZ~64HZ)
Power Factor 0.98
Output
Voltage Regulation 208/220/230/240X (1±2%)VAC
Frequency Regulation 50/60 Hz±0.05Hz
Power Factor 0.7/0.8 (Optional)Standard 0.7
Voltage Distortion Linear load<3% Non-linear load<6%
Overload Capability 105%~130% for 10 min;≥130% for 1 min
Current Crest Ratio 3:1
Transfer Time 0ms (AC mode→Battery mode)
Battery
DC Voltage 240VDC
Recharge Time 7 hours to 90% of capacity after full load discharge
Recharge Current 2A 4.2A 2A 4.2A
Display
LCD Display input/output Voltage, Frequency, Battery voltage, Battery capacity, Loading rate.
Communication
Interface Smart RS232, SNMP(Optional),USB (Optional)
Environment
Operation Temperature 0~40℃
Humidity 0~95% (Non-condensing)
Storage Temperature -25℃~55℃
Sea Level Elevation <1500m
Noise Level (1m) <55dB
Physics Characteristic
Weight
(KG)
79.0 33.5 81.5 36.0
87.5 39.5 90.0 42.0
Dimensions: Wx D x H )mm 260X570X717
 
 
 
APPLICATION OF OUR PRODUCT

 

1. Living house and home building

2. Office building, factory and warehouse

3. Shopping mall, stadium and so on

4. Power station, field operation and some huge engineer construction

5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip

 

 

 

COMPANY SHOW

 

Introduction of Company

Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.

 

 

 

WHY CHOOSE US ?

 

1, QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.

2, Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.

 

 

FAQ

 

1. How to choose suitable inverter?

 

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

 

For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

 

Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power

.......................................................................................................................................................................

 

2. How do I choose the size of the inverter?

 

Different types of load demand for power are different. You can view the load power values to determine the

size of the power inverter.

 

Notice:

 

Resistive load: you can choose the same power as the load.

 

Capacitive loads: according to the load, you can choose 2-5 times power.

 

Inductive loads: according to the load, you can choose 4-7 times power.

.......................................................................................................................................................................

3. How connection between batteries and an power inverter?

 

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions

.......................................................................................................................................................................

 

4. How to calculate the load of working hours requires configuration of the battery size?

 

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

.......................................................................................................................................................................

 